https://issues.apache.org/jira/browse/TUSCANY-536?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel#action_12465073
]
Jean-Sebastien Delfino commented on TUSCANY-536:
------------------------------------------------
AXIS2C-209 has been fixed, we should remove the workaround and test, in
particular on Windows.
> Cannot mix both WS Entrypoint and WS External Service
> -----------------------------------------------------
>
> Key: TUSCANY-536
> URL: https://issues.apache.org/jira/browse/TUSCANY-536
> Project: Tuscany
> Issue Type: Bug
> Components: C++ SCA
> Affects Versions: Cpp-current, Cpp-M1
> Environment: Windows only
> Reporter: Andrew Borley
> Priority: Minor
> Fix For: Cpp-M3
>
>
> A component invoked via a WS Entrypoint fails after invoking a WS External
> Service. I believe this is a problem with freeing memory in Axis2C & have
> asked a question on the Axis2C mailing list. Currently this causes the server
> to crash.
> A workaround can be used - comment out the block that frees the Axis2C
> service client in Axis2Client.cpp at line 169:
> // if (svc_client)
> // {
> // AXIS2_SVC_CLIENT_FREE(svc_client, env);
> // svc_client = NULL;
> // }
> Unfortunately this can cause memory leakage problems.
--