On Friday, August 22, 2014 at 05:02:37 AM, Li Ye-B37916 wrote: > Hi Marek, > > On 8/22/2014 1:18 AM, Marek Vasut wrote: > > On Thursday, August 21, 2014 at 07:10:32 PM, Fabio Estevam wrote: > >> When testing the FEC driver on a mx6solox we noticed that the TDAR bit > >> gets always cleared prior then the READY bit is set in the last BD, > >> which causes FEC transmission to fail. > >> > >> As explained by Ye Li: > >> > >> "The TDAR bit is set when the descriptors are all out from TX ring, but > >> the descriptor properly is in transmitting not READY. > > > > Again, I do not understand this sentence :-( > > When transmitting data, FEC internal DMA reads the TX descriptor and move > the data from the buffer pointed by TX descriptor to FEC internal FIFO. > All TX descriptors are managed in a ring. We found the TDAR is cleared at > DMA starting last descriptor of the ring, not at DMA having last > descriptor finished. So this bit clears earlier than the READY bit of last > descriptor. The delay is the time for the data sending of last descriptor. > > >> These are two signals, > >> and in Ic simulation, we found the TDAR always clear prior than the > >> READY bit of last BD. > > > > And this is the behavior of which version of the FEC IP, the "old" one or > > the one present in MX6slx ? > > This is the behavior of current FEC IP on mx6sx. For old ones, we did not > do simulation for them, but it seems the TDAR clear at the last TX > descriptor finished.
Thanks for clarification. Fabio, can you please document this with a big comment in the code ? Best regards, Marek Vasut _______________________________________________ U-Boot mailing list [email protected] http://lists.denx.de/mailman/listinfo/u-boot