On Fri, Jun 19, 2015 at 11:39:41PM +0200, Marek Vasut wrote:

> Patch 33fe2fb8df01647f97a7bce96a1c7781a7f6d253 titled
> "mmc: bcm283x: Remove get_timer_us() from mmc driver"
> incorrectly replaced ad-hoc get_timer_us() function
> with a plain get_timer(). The get_timer() operates in
> mSec units instead of uSec though, which caused very
> slow operation of the driver.
> 
> Restore the original behavior of the driver, but avoid
> get_timer_us() and use timer_get_us() instead. The later
> is part of the standard API.
> 
> Signed-off-by: Marek Vasut <[email protected]>
> Cc: Jakub Kiciński <[email protected]>
> Cc: Stephen Warren <[email protected]>
> Tested-by: Jakub Kicinski <[email protected]>

Applied to u-boot/master, thanks!

-- 
Tom