Hi Vladimir, On Sun, Jul 5, 2015 at 11:22 PM, Vladimir Zapolskiy <[email protected]> wrote: > LPC32xx MAC and clock control configuration requires some minor quirks > to deal with a phy connected by RMII. > > It's worth to mention that the kernel and legacy BSP from NXP sets > SUPP_RESET_RMII == (1 << 11) bit, however the description of this bit is > missing in shared LPC32x0 User Manual UM10326 Rev. 3, July 22, 2011 > and in LPC32x0 Draft User Mannual Rev. 00.27, November 20, 2008, also > in my tests an SMSC LAN8700 phy device connected over RMII seems to > work correctly without touching this bit. > > Add support of RMII, if CONFIG_RMII is defined, this option is aligned > with a number of boards, which already define the same config value. > > Signed-off-by: Vladimir Zapolskiy <[email protected]>
Applied to u-boot-net, thanks! -Joe _______________________________________________ U-Boot mailing list [email protected] http://lists.denx.de/mailman/listinfo/u-boot