On 03.06.2016 15:16, Nathan Rossi wrote:
Commit a058052c "net: phy: do not read configuration register on reset",
changes the behaviour of the phy_reset function such that the state of
the BMCR register is not preserved during reset.
Change the config function for the m88e1310 so that it does not do a
reset after configuring auto-negotiation.
Signed-off-by: Nathan Rossi <[email protected]>
Cc: Joe Hershberger <[email protected]>
Cc: Michal Simek <[email protected]>
Cc: Stefan Roese <[email protected]>
Reviewed-by: Stefan Roese <[email protected]>
Thanks,
Stefan
_______________________________________________
U-Boot mailing list
[email protected]
http://lists.denx.de/mailman/listinfo/u-boot