On 09/23/2016 01:15 AM, Alison Wang wrote:
> GENERIC_TIMER_CLK and CONFIG_TIMER_CLK_FREQ are both used to define
> Generic Timer frequency. It is reduplicate. This patch will remove
> GENERIC_TIMER_CLK macro.
>
> Signed-off-by: Alison Wang <alison.w...@nxp.com>
> ---
>  arch/arm/cpu/armv7/ls102xa/psci.S  | 2 +-
>  arch/arm/cpu/armv7/ls102xa/timer.c | 2 +-
>  include/configs/ls1021aqds.h       | 5 -----
>  include/configs/ls1021atwr.h       | 5 -----
>  4 files changed, 2 insertions(+), 12 deletions(-)
>
> diff --git a/arch/arm/cpu/armv7/ls102xa/psci.S 
> b/arch/arm/cpu/armv7/ls102xa/psci.S
> index 8f38680..9efb6d8 100644
> --- a/arch/arm/cpu/armv7/ls102xa/psci.S
> +++ b/arch/arm/cpu/armv7/ls102xa/psci.S
> @@ -36,7 +36,7 @@
>
>       .align  5
>
> -#define      ONE_MS          (GENERIC_TIMER_CLK / 1000)
> +#define      ONE_MS          (CONFIG_TIMER_CLK_FREQ / 1000)
>  #define      RESET_WAIT      (30 * ONE_MS)
>

Alison,

Can you use GENERIC_TIMER_CLK? Recent change in U-Boot doesn't favor 
using CONFIG_* macros.

York