On 2016-10-13 14:36, Jagan Teki wrote:
On Thu, Oct 13, 2016 at 5:48 PM, Gary Thomas <g...@mlbassoc.com> wrote:
I have a device tree property which in the .dts looks like this:
  prop = <1>;

I'd like to be able to pass a 0 or 1 to this property via the 'fdt set'
command, but it seems to only be able to push a string into the field,
which in turn is always interpreted as 0.

How can I push a numeric '1' to my property?  Do I have to change
it to be a string and force my driver to manage those instead of
numeric values?

Did you tried this? for setting 1

U-boot> fdt set <full_path> 'prop' <1>

Yes, that worked perfectly, thanks!

Sorry if this was a simple/FAQ/RTFM question, but I didn't see it anywhere.

--
------------------------------------------------------------
Gary Thomas                 |  Consulting for the
MLB Associates              |    Embedded world
------------------------------------------------------------
_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
http://lists.denx.de/mailman/listinfo/u-boot

Reply via email to