Dear Christophe, In message <1e6c1b5c-2e49-6784-6d6d-f4532aa20...@c-s.fr> you wrote: > > > Like a few lines above, you could/should use a single call to > > clrsetbits_be32() here. And as Heiko already commented, please use > > readable names istead of the magic numbers. > > I shall not use clrsetbits_be32(), because the ERRATA says: > > Program the PLPRCR such that the PLL clock will change, then reprogram > the PLPRCR value back to the desired value
Ah! This is critical information, so please add a comment to explain this. [Otherwise there is the risk some later "optimization" intro- duces a bug.] Best regards, Wolfgang Denk -- DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: (+49)-8142-66989-10 Fax: (+49)-8142-66989-80 Email: w...@denx.de He had been eight years upon a project for extracting sunbeams out of cucumbers, which were to be put in vials hermetically sealed, and let out to warm the air in raw inclement summers. - Jonathan Swift _Gulliver's Travels_ ``A Voyage to Laputa, etc.'' ch. 5 _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de https://lists.denx.de/listinfo/u-boot