On Mon, Oct 9, 2017 at 6:04 PM, Felix Brack <[email protected]> wrote:
> This patch extends pmic_bind_children prefix matching. In addition to
> the node name the property regulator-name is used while trying to match
> prefixes. This allows assigning different drivers to regulator nodes
> named regulator@1 and regulator@10 for example.

No. See the regulator bindings:

Optional properties:
- regulator-name: A string used as a descriptive name for regulator outputs

This can vary from board to board. The name should match the power rail
name of the board (which may not be the same as the regulator chip's
output name).

If you have multiple regulator nodes which need to be differentiated,
you need to use the deprecated "regulator-compatible" property, or just
use the standard compatible property.

ChenYu
_______________________________________________
U-Boot mailing list
[email protected]
https://lists.denx.de/listinfo/u-boot

Reply via email to