On Wed, Oct 23, 2019 at 5:47 AM <[email protected]> wrote:
>
> From: Nicolas Ferre <[email protected]>
>
> The KSZ8081 PHY has a factory test mode which is set at the de-assertion
> of the reset line based on the RXER (KSZ8081RNA/RND) or TXC
> (KSZ8081MNX/RNB) pin. If a pull-down is missing, or if the pin has a
> pull-up, the factory test mode should be cleared by manually writing a 0
> (according to the datasheet).
> Create another ksz8081_config function to handle this case.
>
> Suggested-by: Antoine Tenart <[email protected]>
> Signed-off-by: Nicolas Ferre <[email protected]>

Acked-by: Joe Hershberger <[email protected]>