Florian, On Fri, 2020-02-21 at 11:54 +0100, Nicolas Saenz Julienne wrote: > Hi Matthias, > > On Thu, 2020-02-20 at 19:58 +0100, Matthias Brugger wrote: > > On 20/02/2020 17:36, Nicolas Saenz Julienne wrote: > > > As per Linux's driver, ID_MODE_DIS is only set when the PHY interface is > > > RGMII. Don't enable it for the rest of setups. > > > > > > This has been seen to misconfigure RPi4's PHY when booting Linux. > > > > > > Signed-off-by: Nicolas Saenz Julienne <[email protected]> > > > --- > > > drivers/net/bcmgenet.c | 5 ++++- > > > 1 file changed, 4 insertions(+), 1 deletion(-) > > > > > > diff --git a/drivers/net/bcmgenet.c b/drivers/net/bcmgenet.c > > > index 8f4848aec6..e971b556ac 100644 > > > --- a/drivers/net/bcmgenet.c > > > +++ b/drivers/net/bcmgenet.c > > > @@ -448,7 +448,10 @@ static int bcmgenet_adjust_link(struct > > > bcmgenet_eth_priv *priv) > > > } > > > > > > clrsetbits_32(priv->mac_reg + EXT_RGMII_OOB_CTRL, OOB_DISABLE, > > > - RGMII_LINK | RGMII_MODE_EN | ID_MODE_DIS); > > > + RGMII_LINK | RGMII_MODE_EN); > > > + > > > + if (phy_dev->interface == PHY_INTERFACE_MODE_RGMII) > > > + setbits_32(priv->mac_reg + EXT_RGMII_OOB_CTRL, ID_MODE_DIS); > > > > Is this given because by different DTS? Shouldn't that be uniform on the > > RPi4? > > The interface type is read from DT, the 'phy-mode' property. In the case of > the > RPi4 it's 'rgmii-rxid'. > > The downstream DT used to be configured differently ('rgmii' and using > 'ethernet-phy-ieee802.3-c22'), that's why you might have seen the board > working > at some point with this driver. But as we updated the DT to match upstream's > we > switched to 'rgmii-rxid' which is being misconfigured as 'rgmii' in u-boot. So > you have u-boot configuring 'rgmii' while Linux configures 'rgmii-rxid', which > fails to clear the ID_MODE_DIS bit. This, I imagine, blocks the delay > configuration process from the PHY (I don't have any documentation).
With this in mind, would it make sens to do this in the Linux driver?
diff --git a/drivers/net/ethernet/broadcom/genet/bcmmii.c
b/drivers/net/ethernet/broadcom/genet/bcmmii.c
index 6392a2530183..10244941a7a6 100644
--- a/drivers/net/ethernet/broadcom/genet/bcmmii.c
+++ b/drivers/net/ethernet/broadcom/genet/bcmmii.c
@@ -294,6 +294,7 @@ int bcmgenet_mii_config(struct net_device *dev, bool init)
*/
if (priv->ext_phy) {
reg = bcmgenet_ext_readl(priv, EXT_RGMII_OOB_CTRL);
+ reg &= ~ID_MODE_DIS;
reg |= id_mode_dis;
if (GENET_IS_V1(priv) || GENET_IS_V2(priv) || GENET_IS_V3(priv))
reg |= RGMII_MODE_EN_V123;
It all comes down to wheter we trust bootloader's config or not.
Regards,
Nicolas
signature.asc
Description: This is a digitally signed message part