> From: Haibo Chen <[email protected]> > On imx6Q/imx6DL, we find if config the DTOCV to 0~3, it will impact > cmd6 behavior, after cmd6 get transfer complete interrupt, the data0 > line will keep low over 5 seconds. This should be a IC bug on imx6Q/DL. > For other platforms, do not has this issue. > To fix this issue, fix the DTOCV to 0xE, the max setting, this also align > with Linux configuration. > Signed-off-by: Haibo Chen <[email protected]> > Reviewed-by: Ye Li <[email protected]> > Reviewed-by: Jaehoon Chung <[email protected]> Applied to u-boot-imx, master, thanks !
Best regards, Stefano Babic -- ===================================================================== DENX Software Engineering GmbH, Managing Director: Wolfgang Denk HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: [email protected] =====================================================================