> From: Haibo Chen <[email protected]>
> On imx6Q/imx6DL, we find if config the DTOCV to 0~3, it will impact
> cmd6 behavior, after cmd6 get transfer complete interrupt, the data0
> line will keep low over 5 seconds. This should be a IC bug on imx6Q/DL.
> For other platforms, do not has this issue.
> To fix this issue, fix the DTOCV to 0xE, the max setting, this also align
> with Linux configuration.
> Signed-off-by: Haibo Chen <[email protected]>
> Reviewed-by: Ye Li <[email protected]>
> Reviewed-by: Jaehoon Chung <[email protected]>
Applied to u-boot-imx, master, thanks !

Best regards,
Stefano Babic

-- 
=====================================================================
DENX Software Engineering GmbH,      Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: +49-8142-66989-53 Fax: +49-8142-66989-80 Email: [email protected]
=====================================================================