On 25.05.21 19:42, Marek Behún wrote:
Setting DM_FLAG_PRE_RELOC for Armada 3720 clock drivers (TBG and
peripheral clocks) makes it possible for serial driver to retrieve clock
rates via clk API.
Signed-off-by: Marek Behún <[email protected]>
Reviewed-by: Stefan Roese <[email protected]>
Thanks,
Stefan
---
drivers/clk/mvebu/armada-37xx-periph.c | 1 +
drivers/clk/mvebu/armada-37xx-tbg.c | 1 +
2 files changed, 2 insertions(+)
diff --git a/drivers/clk/mvebu/armada-37xx-periph.c
b/drivers/clk/mvebu/armada-37xx-periph.c
index b0f47c33b3..3b767d7060 100644
--- a/drivers/clk/mvebu/armada-37xx-periph.c
+++ b/drivers/clk/mvebu/armada-37xx-periph.c
@@ -626,4 +626,5 @@ U_BOOT_DRIVER(armada_37xx_periph_clk) = {
.ops = &armada_37xx_periph_clk_ops,
.priv_auto = sizeof(struct a37xx_periphclk),
.probe = armada_37xx_periph_clk_probe,
+ .flags = DM_FLAG_PRE_RELOC,
};
diff --git a/drivers/clk/mvebu/armada-37xx-tbg.c
b/drivers/clk/mvebu/armada-37xx-tbg.c
index b1c0852e89..054aff5e6a 100644
--- a/drivers/clk/mvebu/armada-37xx-tbg.c
+++ b/drivers/clk/mvebu/armada-37xx-tbg.c
@@ -152,4 +152,5 @@ U_BOOT_DRIVER(armada_37xx_tbg_clk) = {
.ops = &armada_37xx_tbg_clk_ops,
.priv_auto = sizeof(struct a37xx_tbgclk),
.probe = armada_37xx_tbg_clk_probe,
+ .flags = DM_FLAG_PRE_RELOC,
};
Viele Grüße,
Stefan
--