On 25.05.21 19:42, Marek Behún wrote:
Setting DM_FLAG_PRE_RELOC for Armada 3720 clock drivers (TBG and
peripheral clocks) makes it possible for serial driver to retrieve clock
rates via clk API.

Signed-off-by: Marek Behún <[email protected]>

Reviewed-by: Stefan Roese <[email protected]>

Thanks,
Stefan

---
  drivers/clk/mvebu/armada-37xx-periph.c | 1 +
  drivers/clk/mvebu/armada-37xx-tbg.c    | 1 +
  2 files changed, 2 insertions(+)

diff --git a/drivers/clk/mvebu/armada-37xx-periph.c 
b/drivers/clk/mvebu/armada-37xx-periph.c
index b0f47c33b3..3b767d7060 100644
--- a/drivers/clk/mvebu/armada-37xx-periph.c
+++ b/drivers/clk/mvebu/armada-37xx-periph.c
@@ -626,4 +626,5 @@ U_BOOT_DRIVER(armada_37xx_periph_clk) = {
        .ops            = &armada_37xx_periph_clk_ops,
        .priv_auto      = sizeof(struct a37xx_periphclk),
        .probe          = armada_37xx_periph_clk_probe,
+       .flags          = DM_FLAG_PRE_RELOC,
  };
diff --git a/drivers/clk/mvebu/armada-37xx-tbg.c 
b/drivers/clk/mvebu/armada-37xx-tbg.c
index b1c0852e89..054aff5e6a 100644
--- a/drivers/clk/mvebu/armada-37xx-tbg.c
+++ b/drivers/clk/mvebu/armada-37xx-tbg.c
@@ -152,4 +152,5 @@ U_BOOT_DRIVER(armada_37xx_tbg_clk) = {
        .ops            = &armada_37xx_tbg_clk_ops,
        .priv_auto      = sizeof(struct a37xx_tbgclk),
        .probe          = armada_37xx_tbg_clk_probe,
+       .flags          = DM_FLAG_PRE_RELOC,
  };



Viele Grüße,
Stefan

--
DENX Software Engineering GmbH,      Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-51 Fax: (+49)-8142-66989-80 Email: [email protected]

Reply via email to