On Mon, Jul 19, 2021 at 9:15 PM Fabio Estevam <[email protected]> wrote: > > Do not pass the console baudrate to the 'console' variable > to avoid the baudrate being passed twice when extlinux.conf > contains the standard: console=${console},${baudrate} format.
Maybe we could deal with this using the stdout-path method in DT? > cat /proc/cmdline > root=PARTUUID=00000000-01 rootwait rw console=ttymxc0,115200,115200 > > Signed-off-by: Fabio Estevam <[email protected]> > --- > include/configs/mx6cuboxi.h | 3 +-- > 1 file changed, 1 insertion(+), 2 deletions(-) > > diff --git a/include/configs/mx6cuboxi.h b/include/configs/mx6cuboxi.h > index 1a06f29b8c17..9e5083b0d876 100644 > --- a/include/configs/mx6cuboxi.h > +++ b/include/configs/mx6cuboxi.h > @@ -38,7 +38,6 @@ > /* Command definition */ > > #define CONFIG_MXC_UART_BASE UART1_BASE > -#define CONSOLE_DEV "ttymxc0" > > #ifndef CONFIG_SPL_BUILD > #define CONFIG_EXTRA_ENV_SETTINGS \ > @@ -54,7 +53,7 @@ > "ramdiskaddr=0x13000000\0" \ > "initrd_high=0xffffffff\0" \ > "ip_dyn=yes\0" \ > - "console=" CONSOLE_DEV ",115200\0" \ > + "console=ttymxc0\0" \ > "bootm_size=0x10000000\0" \ > "mmcdev=" __stringify(CONFIG_SYS_MMC_ENV_DEV) "\0" \ > "finduuid=part uuid mmc 1:1 uuid\0" \ > -- > 2.25.1 >