On Thu, 28 Oct 2021 at 05:18, Heinrich Schuchardt
<heinrich.schucha...@canonical.com> wrote:
>
> On 8/22/21 22:41, Samuel Holland wrote:
> > Currently, the wdt_reboot driver always gets its watchdog device
> > reference from an OF node. This prevents selecting a watchdog at
> > runtime. Move the watchdog device reference to the plat data, so
> > the driver can be bound with the reference pre-provided. The
> > reference will still be acquired from the OF node if it is not
> > already provided.
> >
> > Signed-off-by: Samuel Holland <sam...@sholland.org>
>
> Reviewed-by: Heinrich Schuchardt <heinrich.schucha...@canonical.com>

Reviewed-by: Simon Glass <s...@chromium.org>