On 27.04.22 12:41, Marek Behún wrote:
From: Marek Behún <marek.be...@nic.cz>
Drop one indentation level in the mvneta_adjust_link() function.
Signed-off-by: Marek Behún <marek.be...@nic.cz>
Reviewed-by: Stefan Roese <s...@denx.de>
Thanks,
Stefan
---
drivers/net/mvneta.c | 38 ++++++++++++++++++--------------------
1 file changed, 18 insertions(+), 20 deletions(-)
diff --git a/drivers/net/mvneta.c b/drivers/net/mvneta.c
index 72789fc5c6..66d5e10174 100644
--- a/drivers/net/mvneta.c
+++ b/drivers/net/mvneta.c
@@ -1161,31 +1161,29 @@ static void mvneta_adjust_link(struct udevice *dev)
return;
}
- if (phydev->link) {
- if ((pp->speed != phydev->speed) ||
- (pp->duplex != phydev->duplex)) {
- u32 val;
+ if (phydev->link &&
+ (pp->speed != phydev->speed || pp->duplex != phydev->duplex)) {
+ u32 val;
- val = mvreg_read(pp, MVNETA_GMAC_AUTONEG_CONFIG);
- val &= ~(MVNETA_GMAC_CONFIG_MII_SPEED |
- MVNETA_GMAC_CONFIG_GMII_SPEED |
- MVNETA_GMAC_CONFIG_FULL_DUPLEX |
- MVNETA_GMAC_AN_SPEED_EN |
- MVNETA_GMAC_AN_DUPLEX_EN);
+ val = mvreg_read(pp, MVNETA_GMAC_AUTONEG_CONFIG);
+ val &= ~(MVNETA_GMAC_CONFIG_MII_SPEED |
+ MVNETA_GMAC_CONFIG_GMII_SPEED |
+ MVNETA_GMAC_CONFIG_FULL_DUPLEX |
+ MVNETA_GMAC_AN_SPEED_EN |
+ MVNETA_GMAC_AN_DUPLEX_EN);
- if (phydev->duplex)
- val |= MVNETA_GMAC_CONFIG_FULL_DUPLEX;
+ if (phydev->duplex)
+ val |= MVNETA_GMAC_CONFIG_FULL_DUPLEX;
- if (phydev->speed == SPEED_1000)
- val |= MVNETA_GMAC_CONFIG_GMII_SPEED;
- else if (pp->speed == SPEED_100)
- val |= MVNETA_GMAC_CONFIG_MII_SPEED;
+ if (phydev->speed == SPEED_1000)
+ val |= MVNETA_GMAC_CONFIG_GMII_SPEED;
+ else if (pp->speed == SPEED_100)
+ val |= MVNETA_GMAC_CONFIG_MII_SPEED;
- mvreg_write(pp, MVNETA_GMAC_AUTONEG_CONFIG, val);
+ mvreg_write(pp, MVNETA_GMAC_AUTONEG_CONFIG, val);
- pp->duplex = phydev->duplex;
- pp->speed = phydev->speed;
- }
+ pp->duplex = phydev->duplex;
+ pp->speed = phydev->speed;
}
if (phydev->link != pp->link) {
Viele Grüße,
Stefan Roese
--
DENX Software Engineering GmbH, Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany