Hi Heinrich, On Thu, 29 Dec 2022 at 03:18, Heinrich Schuchardt <[email protected]> wrote: > > Hello Simon, > > the sandbox prints the following line when started: > "Reset Status: WARM Reset Status: COLD"
This seems to be when you use the -T flag. > > This does not make much sense. Either the last reset was WARM or COLD > but not both. > Indeed! > sandbox_sysreset_get_status() and sandbox_warm_sysreset_get_status() > should determine the reset status before printing anything incorrect. > > After executing the reset command > > state->last_sysreset == 4 > > This cannot be correct. It seems to be due to: > > arch/sandbox/cpu/state.c:365: state->last_sysreset = SYSRESET_COUNT; > > state_reset_for_test() should only be called in tests. It needs to be called at init also. But actually the name is confusing. How about state_reset_common() or something like that? For testing we have two sysreset devices. Perhaps print_resetinfo() should only print the first? Regards, Simon