On 03.02.23 19:51, Tom Rini wrote:
> On Fri, Feb 03, 2023 at 01:26:37PM +0100, Jan Kiszka wrote:
> 
>> From: Jan Kiszka <jan.kis...@siemens.com>
>>
>> There are many ways to get a signed firmware for the IOT2050 devices,
>> namely for the parts under user-control. This script documents one way
>> of doing it, given a signing key. Augment the board documentation with
>> the required procedure around it.
>>
>> Signed-off-by: Jan Kiszka <jan.kis...@siemens.com>
> [snip]
>> +# currently broken in upstream
>> +#source/tools/binman/binman replace -i flash.bin -f f...@0x380000.fit 
>> fit@0x380000
>> +dd if=f...@0x380000.fit of=flash.bin bs=$((0x1000)) 
>> seek=$((0x380000/0x1000)) conv=notrunc
> 
> Is that still a true comment?
> 

binman: Node '/fit@0x380000/images/u-boot': Offset 0x0 (0) size 0xb8870
(755824) is outside the section '/fit@0x380000' starting at 0x0 (0) of
size 0x400 (1024)

And for the second call:

binman: Node '/fit@0x380000': Replacing sections is not implemented yet

We tried fixing but eventually had to give up. binman is not easy to
understand in these corners.

Jan

-- 
Siemens AG, Technology
Competence Center Embedded Linux

Reply via email to