On 5/2/23 08:51, Eugen Hristev wrote:
regulator_set_enable_if_allowed already handles cases when the
regulator is already enabled, or already disabled, and does not
treat these as errors.
With this change, the driver can work correctly even if the regulator
is already taken or already disabled by another consumer.

Can that ever happen for Vbus supply (the 5V coming out of USB port) ?
Can you elaborate how ?