On Wed, Aug 23, 2023 at 02:26:36PM -0300, Fabio Estevam wrote:
> From: Fabio Estevam <[email protected]>
> 
> The temperature unit is millidegree Celsius, so divide by 1000 to correctly
> print the temperature values in Celsius.
> 
> While at it, also change a typo: "has beyond" to "is beyond".
> 
> Signed-off-by: Fabio Estevam <[email protected]>
> ---
>  drivers/thermal/imx_tmu.c | 4 ++--
>  1 file changed, 2 insertions(+), 2 deletions(-)
> 
> diff --git a/drivers/thermal/imx_tmu.c b/drivers/thermal/imx_tmu.c
> index d9a04eaf79..f79b583811 100644
> --- a/drivers/thermal/imx_tmu.c
> +++ b/drivers/thermal/imx_tmu.c
> @@ -238,8 +238,8 @@ int imx_tmu_get_temp(struct udevice *dev, int *temp)
>               return ret;
>  
>       while (cpu_tmp >= pdata->alert) {
> -             dev_info(dev, "CPU Temperature (%dC) has beyond alert (%dC), 
> close to critical (%dC) waiting...\n",
> -                      cpu_tmp, pdata->alert, pdata->critical);
> +             dev_info(dev, "CPU Temperature (%dC) is beyond alert (%dC), 
> close to critical (%dC) waiting...\n",
> +                      cpu_tmp / 1000, pdata->alert / 1000, pdata->critical / 
> 1000);
>               mdelay(pdata->polling_delay);
>               ret = read_temperature(dev, &cpu_tmp);
>               if (ret)

To follow-up on the patch about select'ing LOG, this shouldn't be
dev_info, it should be higher, at least warning if not critical.  And
given the default LOGLEVEL of 4, it will be included and printed.

-- 
Tom

Attachment: signature.asc
Description: PGP signature

Reply via email to