Adjust the debug UART clock frequency from 14745600 Hz to 7372800 Hz
for the QCS615 platform. This correction ensures proper UART
communication timing and resolves baud rate miscalculations
that affects early boot console output.

Signed-off-by: Balaji Selvanathan <[email protected]>
---
 configs/qcom_qcs615_defconfig | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/configs/qcom_qcs615_defconfig b/configs/qcom_qcs615_defconfig
index 2468267b955..f0362aa6976 100644
--- a/configs/qcom_qcs615_defconfig
+++ b/configs/qcom_qcs615_defconfig
@@ -12,7 +12,7 @@ CONFIG_DEBUG_UART=y
 CONFIG_DEBUG_UART_ANNOUNCE=y
 CONFIG_DEBUG_UART_BASE=0x880000
 CONFIG_DEBUG_UART_MSM_GENI=y
-CONFIG_DEBUG_UART_CLOCK=14745600
+CONFIG_DEBUG_UART_CLOCK=7372800
 
 CONFIG_DEFAULT_DEVICE_TREE="qcom/qcs615-ride"
 
-- 
2.34.1