Hi Peng On Tue, Jan 13, 2026 at 8:44 AM Peng Fan <[email protected]> wrote: > > On Sun, Jan 11, 2026 at 09:23:45AM +0100, Michael Trimarchi wrote: > >This series addresses two significant issues in the pfuze100 regulator driver > >regarding voltage calculation accuracy. > > > >The first patch fixes the handling of the "high range" bit. PFUZE chips > >support > >two voltage ranges (controlled by a register bit) with different step sizes > >and base voltages. Previously, the driver assumed the low range, leading to > >incorrect voltage settings on boards configured for the high range. > > > >The second patch corrects the interpretation of min_uV. The driver was > >incorrectly using the device tree's regulator-min-microvolt constraint as the > >mathematical base (zero-index) for voltage calculations. This caused offset > >errors whenever the DTS constraint differed from the hardware's absolute > >minimum. > >The patch introduces physical minimums in the driver descriptors to ensure > >calculations are based on the datasheet specifications, treating the DTS > >value > >strictly as a safety constraint. > > > >Together, these changes align the U-Boot driver logic with the Linux kernel > >implementation and ensure correct voltage output. > > > >Michael Trimarchi (2): > > power: regulator: pfuze100: support high voltage range bit > > power: regulator: pfuze100: Decouple hardware base voltage from DTS > > constraints > > > Please do not submit three version in one day. That only shows patches > are not developed in good shape. > > The changes looks good to me, but I would like to see which platforms > are tested with the patchset before apply. >
I have tested on a new imx6dl design but I can ask Dario to test on some other imx6 board, do I need to include it in the next release? I will send some other patches end of this week Michael > Thanks, > Peng -- Michael Nazzareno Trimarchi Co-Founder & Chief Executive Officer M. +39 347 913 2170 [email protected] __________________________________ Amarula Solutions BV Joop Geesinkweg 125, 1114 AB, Amsterdam, NL T. +31 (0)85 111 9172 [email protected] www.amarulasolutions.com