On 17/08/2012 23:03, Benoît Thébaudeau wrote:
>
> OK, then for mx25/35/5/6, would you like in timer.c something like:
> #ifdef CONFIG_SYS_MX{*}_CLK32
> #define CLK_32KHZ CONFIG_SYS_MX{*}_CLK32
> #else
> #define CLK_32KHZ 32768
> #endif
>
> {*}: 25, 35, 5 or 6
>
> In that way, this definition could be removed from most boards, and that would
> still allow exceptions and be future-proof.
Yes, this is exactly what I meant.
Best regards,
Stefano
--
=====================================================================