Hi Marek,

On Wed, Sep 23, 2026 at 03:30:44PM +0200, Marek Vasut wrote:
> On 9/22/26 10:42 PM, Stefan Eichenberger wrote:
> 
> Hello Stefan,
> 
> > +   rc = clk_get_by_name(dev, "ref", &clk);
> > +   if (rc)
> > +           rc = clk_get_by_name(dev, "ref_clk", &clk);
> > +   /*
> > +    * Only fall back to the parent node's clocks if the parent is a
> > +    * dwc3 glue wrapper. When the generic node is a top level node,
> > +    * the parent is not the glue device but a bus or the root device,
> > +    * and its clocks are unrelated to the controller.
> > +    */
> > +   if (rc && dev->parent && strstr(dev->parent->driver->name, "dwc3")) {
> 
> Could dev->parent->driver be NULL ?
> 

It should never be NULL. This could only happen when we define it in the
root node but then it should never bind. However, I guess it's better to
be safe and check for NULL anyways in case something is really wrong. I
will add the check in the next version.

> > +           rc = clk_get_by_name(dev->parent, "ref", &clk);
> > +           if (rc)
> > +                   rc = clk_get_by_name(dev->parent, "ref_clk", &clk);
> > +   }
> > +   if (!rc) {
> > +           priv->ref_clk = clk;
> > +
> > +           rc = clk_enable(&priv->ref_clk);
> > +           if (rc && rc != -ENOSYS)
> > +                   dev_warn(dev, "failed to enable ref clock: %d\n", rc);
> 
> Shouldn't the driver fail to probe if clock cannot be enabled ?

Yes that makes sense, I will change that in the next version.

Regards,
Stefan