You mentioned convdata and convcode but not convidx. Did you run convidx? Then again, the problem could be in your software migration, not your data migration from AIX to Tru64.
Unaligned access usually isn't fatal, by itself, but is sometimes caused by bugs that have other, and fatal, consequences. When unaligned access isn't fatal, you can speed up your system by just suppressing the "unaligned" messages via "uac" but that makes it hard to find and fix the associated bugs (sort of like the justly deprecated (S)uppress option in Pick). In the "unaligned" error messages, after the pid, what is (are) the name(s) of the program(s)? Is the program name always "udt"? If so, are you using makeudt and CALLC? > -----Original Message----- > From: Nick Southwell > > Anyone out there using Unidata with Tru64 > on Alphas. We have having a lot of trouble with > unaligned access pid messages. > > Open and Direct Group Limited > London, EC4A 1BD The information contained in this e-mail message may be privileged and confidential information and is intended only for the use of the individual and/or entity identified in the alias address of this message. If the reader of this message is not the intended recipient, or an employee or agent responsible to deliver it to the intended recipient, you are hereby requested not to distribute or copy this communication. If you have received this communication in error, please notify us immediately by telephone or return e-mail and delete the original message from your system. ------- u2-users mailing list [EMAIL PROTECTED] To unsubscribe please visit http://listserver.u2ug.org/
