We do this very thing in a number of our utility programs. We catalog the program and then append a "K" to the characters that appear in field 4 of the generated VOC entry.
So field 4 is "BNK" (in our case) - the "K" means "Keep any select list active". Eg. One of ours looks like this: 0001: V 0002: *dedp*PROGS 0003: B 0004: BNK Adrian -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Barry Brevik Sent: Tuesday, 26 October 2004 7:44 AM To: U2-users (E-mail) Subject: [U2] [UV] Exit BASIC program with SELECT list? Is it possible to create a SELECT list inside a BASIC program, then make that list be the active SELECT list 0 after the program terminates? In other words, I want to build lists in a program, and when I return to TCL I want to see the >> prompt and have an active select list. Any ideas? Barry ------- u2-users mailing list [EMAIL PROTECTED] To unsubscribe please visit http://listserver.u2ug.org/ ------- u2-users mailing list [EMAIL PROTECTED] To unsubscribe please visit http://listserver.u2ug.org/