We do this very thing in a number of our utility programs.

We catalog the program and then append a "K" to the characters that
appear in field 4 of the generated VOC entry.

So field 4 is "BNK" (in our case) - the "K" means "Keep any select list
active".

Eg. One of ours looks like this:

0001: V
0002: *dedp*PROGS
0003: B
0004: BNK

Adrian 

-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Barry Brevik
Sent: Tuesday, 26 October 2004 7:44 AM
To: U2-users (E-mail)
Subject: [U2] [UV] Exit BASIC program with SELECT list?

Is it possible to create a SELECT list inside a BASIC program, then make
that list be the active SELECT list 0 after the program terminates?

In other words, I want to build lists in a program, and when I return to
TCL I want to see the >> prompt and have an active select list.

Any ideas?

Barry
-------