There is no way to get wIntegrate to "share" the device license key that is
used by another UniObjects application.

I recently raised this with IBM and they confirmed that it is not possible so
if you have a client PC running a Uniobjects program and a wInegrate session
then they are going to consume 2 "normal" licenses but you will be able to get
20 device sessions (10 each).

________________________________

From: [EMAIL PROTECTED] on behalf of David Jordan
Sent: Thu 09/12/2004 20:19
To: [EMAIL PROTECTED]
Subject: RE: [U2] Do we need to put a value in UniObject SubKeys



I have been investigating this further, whether we need to actually apply a
value to subkey in a uniobject client as the IBM documentation explains what
it is, but does not say that anything should be done.

My concern is, if we feed a value into subkey that this would then be
different to the ODBC and wintegrate/dynamic connect subkeys, how does this
then allow the server to recognise that these calls all came from the same
desktop.

I ran a test with a VB program without entering a subkey value and then ran
it multiple times from the desktop.  Running uvlictool this multiple
sessions but they only used one licensed seat which is correct.

I then ran dynamic connect and a session of the VB program and again
uvlictool showed multiple sessions that only took one licensed seat.

However when I ran dynamic connect and multiple VB sessions, the uvlictool
showed 2 seats was consumed. The curly was that the last line said only one
seat was used.  (This may be to do with a bug in the uvlictool that is
supposed to be fixed in the latest release)


        Packages in use:   UVCS
2 license seats are in use.
3 license seats are available.

        Packages in use:
        UVCS has 5 licensed seats and 1 in use.




At the moment I assume we do not need to enter a subkey value.  Can anyone
else confirm this?

Regards

David Jordan
-------
u2-users mailing list
[EMAIL PROTECTED]
To unsubscribe please visit http://listserver.u2ug.org/




The information contained in this email is strictly confidential and for the
use of the addressee only, unless otherwise indicated.  If you are not the
intended recipient, please do not read, copy, use or disclose to others this
message or any attachment.  Please also notify the sender by replying to this
email or by telephone +44 (0)20 7896 0011 and then delete the email and any
copies of it.  Opinions, conclusions (etc.) that do not relate to the official
business of this company shall be understood as neither given nor endorsed by
it.  IG Markets Limited and IG Index Plc are authorised and regulated by the
Financial Services Authority and, in Australia, by the Australian Securities
and Investments Commission.

[demime 1.01d removed an attachment of type application/ms-tnef which had a 
name of winmail.dat]
-------
u2-users mailing list
[EMAIL PROTECTED]
To unsubscribe please visit http://listserver.u2ug.org/

Reply via email to