Mike:
Your program illustrates my problem. Any other ideas? When I direct output
to a hold file it looks like:
< 1 > Top of "P_0000" in "PEQS", 561 lines, 1,438 characters.
*--:
547:
548: Page 9
549: Paul's Produce
550: ^012
551: TEST 10
552: LINE 1
553: LINE 2
554: LINE 3
555: LINE 4
556: LINE 5
557: LINE 6
558: LINE 7
559: LINE 8
560: LINE 9
561: LINE 10
Bottom.
All UDT.OPTIONS are OFF except the following:
1 Dtademo (0)-> UDT.OPTIONS
2 U_PSTYLEECL ON
3 U_SHLNOPAGE ON
7 U_NOMAKEPAGE ON
15 U_DYNAMICNUL ON
23 U_PK_READNEXT ON
32 U_PI_PRINT_AT ON
34 U_HEADING_DATE ON
43 U_PRM_DETSUP ON
46 U_UNFLUSHDATA ON
48 U_UNBOUNDARY ON
54 U_PROC_KPTSELECT ON
56 U_CONV_BADRETURN ON
64 U_BASIC_FINISH ON
66 U_PICK_NUMERIC_FILES ON
75 U_PROC_DELIMITER ON
78 U_PICK_LOCK ON
83 U_INPUT_ESC ON
89 U_PICKSTYLE_MVSORT ON
92 U_INSENSITIVE_MATCH ON
104 U_TRAIL_FM_TLOAD ON
114 U_NOFORMFEED ON
1 Dtademo (0)-> SETPTR
Unit 0
Width 132
Length 60
Top margin 3
Bot margin 3
Mode 1
Options are:
1 Dtademo (0)-> LISTPTR
Printer...................
Port.......................Status..Comment.........
HPLJ2420 IP_192.168.1.41 Running Dev printer
1 Dtademo (0)-> U2INFO
Platform : INTEL
Operating System : WIN32-2000 Service Pack 4
Porting Date : Wed Jun 29 10:05:40 MDT 2005
UniData Release : Version 7.1.0PE, Build 3146
Ported by : srcman
...Current account logged onto...
E:\DataTrust\DtaDemo
Licensed(UDT+CP)/Effective UdtSqliPhtmPooledTotal
( 2 + 0 ) / 2 10001
UDTNO USRNBR UID USRNAME USRTYPE TTY IP-ADDRESS TIME DATE
1 3096 197615 bill udt pts/1 192.168.1.101 08:34:06 Mar 23
2006
2 2148 197615 bill udt pts/2 192.168.1.101 08:36:05 Mar 23
2006
Bill Haskett
Advantos Systems, Inc.
www.advantos.net
(760)944-5570 (CA)
(360)923-4838 (WA)
> -----Original Message-----
> From: [EMAIL PROTECTED]
> [mailto:[EMAIL PROTECTED] On Behalf Of Mike
> Rajkowski
> Sent: Thursday, March 23, 2006 7:57 AM
> To: [email protected]
> Subject: RE: [U2] [UD] BASIC Footing statement
>
> I did a quick test on the 7.1 PE, and it worked fine. Try
> the following
> on your system and see if it puts the last footer.
>
> Note that the footer I used was described in the online help.
>
> 001: PRINTER ON
> 002: FOOTING "Page 'PL'Paul''s Produce"
> 003: FOR A = 1 TO 10
> 004: PRINT "TEST ":A
> 005: FOR B = 1 TO 10
> 006: PRINT "LINE ":B
> 007: NEXT B
> 008: IF A # 10 THEN
> 009: PAGE
> 010: END
> 011: NEXT A
> 012: PRINTER OFF
>
>
>
> Michael Rajkowski
>
>
> -----Original Message-----
> From: [EMAIL PROTECTED]
> [mailto:[EMAIL PROTECTED] On Behalf Of Bill Haskett
> Sent: Thursday, March 23, 2006 8:10 AM
> To: [email protected]
> Subject: [U2] [UD] BASIC Footing statement
>
> We're finalizing a conversion from D3 to UD and there are a few issues
> remaining. Our client prints footings on all their reports. The
> footing
> doesn't print on the last page of the reports. We've set
> UDT.OPTIONS 64
> ON
> and still no luck.
>
> All their reports, both BASIC and UniQuery, are executed from a BASIC
> program. We've also set UDT.OPTIONS 7 ON to make sure pages aren't
> filled
> on the screen.
>
> Any suggestions would be appreciated. Thanks.
>
> Bill Haskett
> Advantos Systems, Inc.
> www.advantos.net
> (760)944-5570 (CA)
> (360)923-4838 (WA)
> -------
> u2-users mailing list
> [email protected]
> To unsubscribe please visit http://listserver.u2ug.org/
> -------
> u2-users mailing list
> [email protected]
> To unsubscribe please visit http://listserver.u2ug.org/
-------
u2-users mailing list
[email protected]
To unsubscribe please visit http://listserver.u2ug.org/