Oh yes - another change in UniData 7 in this area - I have put both below in the thread to keep them together.
UniData 7.1.3 Issue 8597 - Problem Description UniData -- Beginning at UniData 6.1.0, if a PHANTOM process was launched from a udt session, and that udt session was closed improperly, such as being killed from the shell level, the PHANTOM process terminated. Although this problem may have occurred on any UNIX platform, it was most easily observed on AIX, and has been fixed. UniData 6.1.7 Issue 7427 - Problem Description UniData -- After a PHANTOM process was invoked, entering Ctrl-C at the ECL prompt in the session that invoked the PHANTOM caused the PHANTOM process to stop. This has been fixed. Regards JayJay ------- u2-users mailing list [email protected] To unsubscribe please visit http://listserver.u2ug.org/