I'm running UD 7.1 on Windows 2003 and am trying to use the ON.ABORT command to prevent user access to ECL. According to the UD Commands Reference manual: The ECL ON.ABORT command identifies a command that UniData executes when a UniBasic program aborts. command may be an ECL command, a paragraph, or a directly or globally cataloged UniBasic program. This setting remains in effect until you clear it with the CLEAR.ONABORT command. Reading the UD Windows Admin manual, the following note is made: Note: You can also use the ECL ON.ABORT command to prevent users from accessing the ECL or MS-DOS prompt. ON.ABORT defines a paragraph that executes whenever a UniBasic program aborts. See the UniData Commands Reference for information about ON.ABORT.
If I set ON.ABORT, in the login paragraph, to execute a BASIC main menu program, then press [Ctrl]+C to break out of the main menu, then enter "END" at the "!" debug prompt, I end up at the ECL prompt. I thought the command specified by the ON.ABORT command was supposed to execute (the main menu program). So, how does one keep anyone from getting to ECL by any means? As always, thanks. Bill Haskett ------- u2-users mailing list [email protected] To unsubscribe please visit http://listserver.u2ug.org/