DataStage Server edition does work with UniData. There is a UniData
passive stage in the same group with the UniVerse stage for access to
these files. Now, if you are planning on using the Hashed File stage,
1) that only works with UniVerse files; 2) is a very bad idea since
there is no guarantee IBM/Ascential will continue UV file and Hashed
File compatibility; 3) does not support the unnesting extensions to
normalize multi-values.
DataStage Enterprise edition (AKA "PX" or Parallel Extender, AKA
Torrent) doesn't have either UV or UD stages and thus does not handle
multi-values.
--
Regards,
Clif
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
W. Clifton Oliver, CCP
CLIFTON OLIVER & ASSOCIATES
Tel: +1 619 460 5678 Web: www.oliver.com
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
On Jul 30, 2006, at 6:45 PM, Stephen O'Neal wrote:
Second foot... DataStage only works with UniVerse.
-------
u2-users mailing list
[email protected]
To unsubscribe please visit http://listserver.u2ug.org/