Many thanks!! Actually, the filesytems were correctly mounted, but it was the "df timeouts" that were causing the problem. As soon as I read your email, it clicked and the fix took five, maybe six seconds to implement.
Again, many thanks!! -------------------------------------------------- Charlie Rubeor Senior Database Administrator Wiremold/Legrand 60 Woodlawn Street West Hartford, CT 06110 Tel: 860-233-6251 x3498 Fax: 860-523-3690 Email: [EMAIL PROTECTED] -------------------------------------------------- Doug Miller <[EMAIL PROTECTED]> Sent by: [EMAIL PROTECTED] 05/10/2007 09:28 AM Please respond to [email protected] To [email protected] cc Subject Re: [U2] Unidata error message This error has to do with the filesystem not being mounted while UD is started and accessing dynamic files later on that filesystem. Later releases handle this better but introduce other problems. IIRC (df timeouts) So, have all your UniData filesystems mounted prior to starting UniData or upgrade to a release that has this patched. Get with your support provider on what release that may be. HTH, -Doug At 08:47 AM 5/9/2007, you wrote: >Is anyone familiar with this error message: > >"Warning: Can't find the partition (1074266118) information in shared >memory." Doug Miller [EMAIL PROTECTED] Manager of Technical Services Strategy 7 Dallas TX ------- u2-users mailing list [email protected] To unsubscribe please visit http://listserver.u2ug.org/ ------- u2-users mailing list [email protected] To unsubscribe please visit http://listserver.u2ug.org/