>From your IBM \bin dir:  

You are going to want to run convidx.exe and convdata.exe...you will need some 
switches to get the subdirs.

convdata -r c:\path to where your unidata files live

convidx -r c:\path to where your unidata files live

I run them in DOS manually...

Dawn Janel Davis
Database Manager
[EMAIL PROTECTED]
410-386-8058
 
Carroll Community College
1601 Washington Road
Westminster, MD 21157


-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Kebbon Irwin
Sent: Wednesday, July 23, 2008 2:10 PM
To: [email protected]
Subject: [U2] Unidata PE Question

I have some Unidata accounts that I have ftp'd from a unix box and I would 
like to be able to log in to them on my XP laptop with Unidata PE installed. 
  I get a high-byte/low-byte error message indicating that, at the least, I 
must run some conversions.  I'm not sure what utilities to use to render the 
data accessible.  Any advice?
Thanks,
Kebbon
-------
u2-users mailing list