Doug,
I don't know if this will help, but we had similar issues caused by the way
uo.net handles locking.  If you read and lock a record using one uo.net
connection (using an exclusive read lock) and try to read it using a
different uo.net connection it will not be able to read it.  IIRC it will
hang, waiting for the lock to be released.  Each uo.net connection uses a
different pid, therefore in essence is seen as a different user.
We had to use a method where we make the connection, read the record and
lock it using a different method, controlling the locking internally, and
then disconnect the uo.net session.  
We have requested an enhancement from IBM on this issue, but I am not sure
where it stands.
HTH,
Mike

Michael Dallaire
Senior Applications Developer
IBM Certified Solutions Expert
Mortgage Builder Software, Inc.
Phone: (248) 304-0600 x 103
Fax: (248) 304-0601
[EMAIL PROTECTED]
www.mortgagebuilder.com
 
Providing Outstanding Support 
It's more than just a company philosophy; it's a whole corporate culture
whose foundation is service.
 
Confidentiality Notice 
This transmission may contain confidential information which is intended for
the exclusive use of the intended recipient. Any disclosure, copying,
distribution or use of the contents by anyone other than the intended
recipient is strictly prohibited. If received in error, please reply to the
sender immediately.
-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of doug chanco
Sent: Saturday, August 02, 2008 10:35 AM
To: [email protected]
Subject: [U2] uniobjects help needed!

Hey,

We are having a problem with uniobjects that started a couple of days 
ago. We have a VB app that uses uniobjects to access an aix system 
running universe 10.1 and a few days ago we started getting errors where 
uniobjects would just die, its starting to look like it might be a 
network issue but so far nothing we can discover.

Our Cisco guy is not seeing any errors in the cisco switches, I am not 
seeing any errors on the aix system (5.2.6).

While is may or may not be a universe/uniobjects issue, so far we have 
been stumped as to what the problem is. We even called an IBM uniobjects 
engineer for several hours and he could not find a problem as neither 
could our VAR or IBM tech support for aix.

So I thought I would throw this out to youll who vast knowledge may 
hold the key to the answers we seek! The fact that in the past 3 days I 
have works close to 60 hours is a testimony to the amount of effort we 
have been putting in to try and solve this problem.

Basically what we are seeing that is

Run-TIme error '-2147417848 (80010108)':
Method 'Read' of object 'IUniFileEx' Failed

So any suggestions/thoughts/ideas/crystal balls/magic spells/voodoo 
chants are welcomed!