Mike:
In UD, UniObjects doesn't hit the LOGIN paragraph (verb) but it does hit
the "UOLOGIN" globally cataloged item. One can control a lot from this
program. I'm guessing UV has the same thing.
Bill
------------------------------------------------------------------------
HENDERSON MIKE, MR said the following on 12/7/2009 1:07 PM:
Kate,
IIRC UV Objects don't go through the login paragraph, the auto logout
time is in the unirpcservices file (in your local equivalent of
C:/IBM/unishared/unirpc/)
Regards
Mike
-----Original Message-----
From: [email protected]
[mailto:[email protected]] On Behalf Of Kate Stanton
Sent: Wednesday, 2 December 2009 10:36 a.m.
To: U2 Users List
Subject: [U2] Auto logout time
On Windows UniVerse 10.1.18 (and many versions before, I think),
using UV objects.
User goes through a VOC PA executed when loggin[g] in, including statement
AUTOLOGOUT 60.
He wants the user to stay up for much longer than that, so has changed
the 60 to 360.
It still logs out within the expected 3 hours.
IIRC, there is another place timeout minutes or seconds are set up.
Does anyone know what, where?
TIA, Kate
Kate Stanton
_______________________________________________
U2-Users mailing list
[email protected]
http://listserver.u2ug.org/mailman/listinfo/u2-users