We have 2 different stationary types that I am dealing with: GREENBAR and
GREENBAR.MEX. They are identical to each other for printer class definition
HP5SI in the Set and Reset as well as all other settings. But I can print a
report using GREENBAR and it condenses the text and the print the same
report using GREENBAR.MEX and it does not condense the print.

Is there anywhere else that the GREENBAR.MEX settings are stored? How does
it get triggered to change the font size?

Thanks,
Bruce

-----Original Message-----
From: [email protected]
[mailto:[email protected]] On Behalf Of Dave Davis
Sent: Thursday, January 13, 2011 6:25 AM
To: U2 Users List
Subject: Re: [U2] SB+ printer font changes


The printer class setting - the Set and Reset Sequences.

You need to send it the PCL5 code (if you are using PCL that is) to switch
to condensed print.

We use (27)E(27)(s17H for the set sequence and (27)E for the reset sequence,
for a stationery we set up for 132 columns on 8-1/2 x 11 inch paper.

-----Original Message-----
From: [email protected]
[mailto:[email protected]] On Behalf Of Lunt, Bruce
Sent: Wednesday, January 12, 2011 6:56 PM
To: [email protected]
Subject: [U2] SB+ printer font changes

Hi All,

I have a question about having the printer-font size switch to condensed
when a SB+ report is sent to a laser printer (HP LaserJet) that is wider
than 80 characters. I know that there is a SB+ user group but I cannot log
into that from work and this is a work question. I was hoping that there
would be a few people who are SB+ users to help me. Anyway, I created a
report the same way as other reports that work just fine but this report
refuses to switch from the large font. If I send the report to the screen it
will switch to condensed print but not when I send it to the printer. Is
there something in the printer setup? Printer Class definition? Stationary
type? Or do I add something in the NETPROCESS

Thanks for your help,

Bruce Lunt
_______________________________________________
U2-Users mailing list
[email protected]
http://listserver.u2ug.org/mailman/listinfo/u2-users
<html>
<body>
________________________________ Dave Davis Team Lead, R&amp;D P:
614-875-4910 x108 F: 614-875-4088 E: [email protected]
[http://www.harriscomputer.com/images/signatures/HarrisSchools.gif]
[http://www.harriscomputer.com/images/signatures/DivisionofHarris.gif]
 6110 Enterprise Parkway Grove City, OH 43123 www.harris-schoolsolutions.com
This message is intended exclusively for the individual or entity to which
it is addressed. This communication may contain information that is
proprietary, privileged or confidential  or otherwise legally exempt from
disclosure. If you are not the named addressee, you are not authorized to
read, print, retain, copy or disseminate this message or any part of it. If
you have received this message in error, please notify the sender
immediately  by e-mail and delete all copies of the message. </body> </html>
_______________________________________________
U2-Users mailing list
[email protected]
http://listserver.u2ug.org/mailman/listinfo/u2-users
_______________________________________________
U2-Users mailing list
[email protected]
http://listserver.u2ug.org/mailman/listinfo/u2-users

Reply via email to