*** This bug is a duplicate of bug 37275 *** I think I found the problem, at least at my pc. I am using Hungarian localization on the machine, and so the numbers are written in eg. 2,5 form instead of 2.5 by default. So, when the gamma values are given in a list in this form (line 431): self.availabletargetgammas = [unicode(i18n('1.4')),unicode(i18n('1.6')),unicode(i18n('1.8')),unicode(i18n('2.0')),unicode(i18n('2.2')),unicode(i18n('2.4'))]
all the dots are changed to commas because of the localization procedure. In line 1028, however the program searches for a simple string, without localization: t = self.config.readEntry("targetgamma","2.0") and later in line 1034: t = '2.0' The problem can be solved either by removing i18n from line 431 or by adding it also to lines 1028 and 1034 to get: t = self.config.readEntry("targetgamma",unicode(i18n("2.0"))) and t = unicode(i18n('2.0')) respectively. -- Display applet does not start https://launchpad.net/bugs/32915 -- kubuntu-bugs mailing list kubuntu-bugs@lists.ubuntu.com https://lists.ubuntu.com/mailman/listinfo/kubuntu-bugs