** Summary changed: - wrong console on shutdown + messages goes to wrong console on shutdown
** Description changed: Ubuntu version 8.10 Intrepid Ibex with Kernel 2.6.27.11 - I keep "splash" disabled in /boot/grub/menu.list to see all the log OK/ERROR at power-on. + I keep "splash" disabled in /boot/grub/menu.list to see all the log OK/ERROR at power-on/off. Power on, GNOME logon, all work ok. - O got the 6 consoles, the first with boot messages, the 7th with X. + I got the 6 consoles, the first with boot messages, plus the 7th with X. After choose shutdown, GNOME logout, X close, the screen switch to console 1, but the poweroff messages goes to console 7. So to see log messages, I have to manually switch to console 7 with CTRL-ALT-7. - This doeas not happened with Ubuntu versione 8.04 Hardy Heron and + This does not happened with Ubuntu version 8.04 Hardy Heron and previous. -- messages goes to wrong console on shutdown https://bugs.launchpad.net/bugs/383894 You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. -- ubuntu-bugs mailing list [email protected] https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs