So, forgetting what the documentation says, looks like as we have 3
possible cases:
1. hwmonX contains directly the sensors data; hwmonX/device doesn't exist
2. hwmonX contains directly the sensors data; hwmonX/device exists but is
irrelevant
3. hwmonX doesn't contain the sensors data, they are in hwmonX/device
Case 1 is covered by conky, either patched or unpatched
Case 2 would cause the unpatched conky to fail
Case 3 would cause the patched conky to fail
I can prepare a patch that covers all these cases but I can't guarantee
that this will go in before karmic is released.
** Changed in: conky (Ubuntu)
Status: Fix Released => In Progress
** Changed in: conky (Ubuntu)
Assignee: (unassigned) => Cesare Tirabassi (norsetto)
--