I hope it gets sorted also. And I am happy I noticed this as this is quite a sneaky bug / behaviour change. I have a 4 disk raid 5 array in a server, and I only started looking into disk spindown because I was suspicious of getting more SMART temperature warnings after upgrading to 10.04.
In any case I don't think I know enough about udev / hdparm to start fixing anything. But as a temporary workaround for disk spindown I added the following to "/etc/rc.local". # workaround for hdparm disk spindown in 10.04 (echo "\n$(date)" && for devname in $(cat /etc/hdparm.conf | grep -o "/dev/sd[a-z]"); do export DEVNAME="$devname" && (/lib/udev/hdparm || true); done) >> /var/log/hdparm_fix.log This looks into "/etc/hdparm.conf", gets all "sd*" device names and then runs "/lib/udev/hdparm" script in the same way the "/lib/udev/rules.d/85-hdparm.rules" rule does. This helps to set the settings I have in "/etc/hdparm.conf" during boot. For new devices plugged into the system after boot, the standard rule should work just fine. In case if anybody uses it, check the "/var/log/hdparm_fix.log" after boot to make sure it set the settings you have in your config. When this problem will be resolved, I will just remove the line. -- [Lucid] hdparm.conf change doesn't have effect https://bugs.launchpad.net/bugs/568120 You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. -- ubuntu-bugs mailing list [email protected] https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs