sysvinit's telinit only ever sends SIGHUP, no matter what the argument.
Upstart's 'telinit u' sends SIGTERM.  busybox init interprets that as a
reboot request.

This regression happened because libc6.postinst was simplified in line
with Debian.  We need to be more careful somehow, to avoid sending
SIGTERM to non-Upstart instances of init.

** Package changed: debian-installer (Ubuntu) => eglibc (Ubuntu)

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/694772