This bug was fixed in the package upstart - 0.6.7-7
---------------
upstart (0.6.7-7) natty; urgency=low
* Re-add upstream r977 to allow proper re-exec on shutdown (LP: #672177)
* debian/control: adding Breaks on eglibc version that disables
telinit u to avoid accidentally installing a version of libc6 that
will cause upstart to re-exec and lose its state.
-- Clint Byrum <[email protected]> Fri, 21 Jan 2011 08:39:13 -0800
** Changed in: upstart (Ubuntu Natty)
Status: In Progress => Fix Released
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/672177
Title:
libc6 upgrade causes umount to fail on shutdown because init cannot be
restarted
--
ubuntu-bugs mailing list
[email protected]