Public bug reported:
Using nomachines nx, I'm having rootless session on a ubuntu 11.04
I can't change focus to nx windows using alt-tab.
>From digging into mutter code I see that nx windows gives bad timestamp
when having _NET_WM_USER_TIME changed.
For example, local windows having timestamp of 58806978, while nx windows are
having a timestamp of 1725594813.
It seems that nx windows timestamp is based on a different time than the local
windows.
I'm not an X expert.
If I'm understanding right, there is a timer in the local X server, which gives
timestamps. But nx windows get their timestamp from their xserver which is the
nxagent. and this property is somehow forwarded to the local X.
Please fix me if I'm mistaken.
So if the timestamps of nx windows are origined from a differnet timer,
how could it be compared to local timestamps?
My environment details:
Description: Ubuntu 11.04
Release: 11.04
libmutter0:
Installed: 3.0.2.1-2ubuntu2~natty1
Candidate: 3.0.2.1-2ubuntu2~natty1
Version table:
3.0.2.1-2ubuntu2~natty1 0
500 http://ppa.launchpad.net/gnome3-team/gnome3/ubuntu/ natty/main
amd64 Packages
*** 3.0.2.1-2ubuntu2~natty1 0
100 /var/lib/dpkg/status
nxclient:
Installed: (none)
Candidate: (none)
Version table:
3.5.0-7 0
100 /var/lib/dpkg/status
** Affects: mutter (Ubuntu)
Importance: Undecided
Status: New
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/849762
Title:
nomachines nx windows can't get focus
To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/mutter/+bug/849762/+subscriptions
--
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs