It seems that with the newest version of the USB CUPS backend as it is
currently used in the Precise CUPS SRU (1.5.3-0ubuntu2) and in CUPS
1.5.4 and 1.6.x upstream (1.6.0 currently in Quantal) Canon printers do
not work any more, having the last portion of the last page cut off.

One of the changes in the new USB backend is that a port reset is done
in the end of the job to clean up. This reset fixes other bugs and does
not cause any problem for non-Canon printers. I will add a quirk handler
to the USB backend which suppresses the reset for Canon printers.

See also the upstream bug report http://www.cups.org/str.php?L4155


** Changed in: cups (Ubuntu)
   Importance: Undecided => Critical

** Changed in: cups (Ubuntu)
       Status: Confirmed => Triaged

** Also affects: cups (Ubuntu Precise)
   Importance: Undecided
       Status: New

** Changed in: cups (Ubuntu Precise)
       Status: New => Triaged

** Changed in: cups (Ubuntu Precise)
   Importance: Undecided => Critical

** Tags added: regression-update

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1032456

Title:
  Canon i560 prints half a page after 20120801 upgrade to
  v1.5.3-0ubuntu2

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/cups/+bug/1032456/+subscriptions

-- 
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs