This bug was fixed in the package ifupdown - 0.7.5ubuntu2
---------------
ifupdown (0.7.5ubuntu2) raring; urgency=low
* Update network-interface-security job to stop when the parent job is
stopped itself. This avoids leftover instances. (LP: #1065684)
* Set mtu of tunnel devices. (LP: #1074048)
* Actually set the new calculated value for duplicate entries. (LP: #1086517)
-- Stephane Graber <[email protected]> Tue, 11 Dec 2012 19:53:56 -0500
** Changed in: ifupdown (Ubuntu)
Status: Fix Committed => Fix Released
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1074048
Title:
When setting up a GRE tunnel through the 'tunnel' method, the mtu
parameter is not respected
To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/ifupdown/+bug/1074048/+subscriptions
--
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs