What is strange is the response RDR_to_PC_SlotStatus (first byte 81h) when a card is present and powered. The normal CCID frame should be: 81 00 00 00 00 00 xx _00_ 00 00 00 is: An ICC is present and active (power is on and stable, RST is inactive)
But in the case of the HP we have: 81 00 00 00 00 00 xx _01_ 00 01 01 is: An ICC is present and inactive (not activated or shut down by hardware error) The last 01 is: Clock stopped in state L Something (the reader? the BIOS?) decided to stop the reader clock. I need more information about your Alcor Micro reader. Please follow http://pcsclite.alioth.debian.org/ccid.html#CCID_compliant -- You received this bug notification because you are a member of Ubuntu Bugs, which is subscribed to Ubuntu. https://bugs.launchpad.net/bugs/1307109 Title: Alcor Micro AU9540 keeps powering down when card is present To manage notifications about this bug go to: https://bugs.launchpad.net/ubuntu/+source/linux/+bug/1307109/+subscriptions -- ubuntu-bugs mailing list [email protected] https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs