I could not easily find this workaround from a google search so
documenting it here:

Typical "use with caution" notice, may cause a (small) rift in the
space-time continuum, etc.

Edit /lib/udev/rules.d/95-upower-csr.rules (with sudo), comment out
(with #) the last set of lines at the bottom so that it's left like
this:

# Unifying HID++ devices
#SUBSYSTEM!="hid", GOTO="up_unifying_end"
#ATTRS{idVendor}=="046d", ENV{UPOWER_VENDOR}="Logitech, Inc."
#ATTRS{idVendor}=="046d", ATTRS{idProduct}=="c52b", 
DRIVER=="logitech-djdevice", ENV{UPOWER_BATTERY_TYPE}="unifying"
#ATTRS{idVendor}=="046d", ATTRS{idProduct}=="c532", 
DRIVER=="logitech-djdevice", ENV{UPOWER_BATTERY_TYPE}="unifying"
#ATTRS{idVendor}=="046d", ATTRS{idProduct}=="c52f", 
ENV{UPOWER_BATTERY_TYPE}="lg-wireless"
LABEL="up_unifying_end"

^Everything commented out but that last LABEL.

On the next reboot, UPower will completely ignore these Unifying
devices!

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1315434

Title:
  Mouse with no time remaining estimate showing in preference to battery
  being charged

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/indicator-power/+bug/1315434/+subscriptions

-- 
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs