Public bug reported:
hplip installs 56-hpmud.rules in /lib/udev/rules.d/, which comes *after*
40-libsane.rules. For HP scanners recognized by 56-hpmud.rules, but not
by 40-libsane.rules, ENV{libsane_matched} is set to ‘yes’, which is
correct. But as 56-hpmud.rules is evaluated *after* 40-libsane.rules,
the rule from 40-libsane.rules which has ‘RUN+="/bin/setfacl -m
g:scanner:rw $env{DEVNAME}"’ is not executed anymore. This leads to the
ACLs for the scanner group *not* being set for the device.
In my case, the device is 03f0:4f11 (an HP OfficeJet 5610, known as
“Hewlett-Packard OfficeJet 5600”). hplip version is 3.14.3-0ubuntu3.2 on
Ubuntu 14.04.2 LTS (trusty).
What I tried: copied /lib/udev/rules.d/56-hpmud.rules to
/etc/udev/rules.d/10-localoverride.rules – worked fine, ACLs set
properly.
** Affects: hplip (Ubuntu)
Importance: Undecided
Status: New
--
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1458329
Title:
hplip has wrong order of udev rules ⇒ scanner ACLs not set