Public bug reported:

Since some time (while running 14.10) I get strange estimates of remaining 
battery time, and the laptop dies with about 50-60% remaining. 
I think the problem is related to the huge difference between energy-full and 
enegry-full-design (see attached upower.dump). The same numbers are reported by 
acpi -V.

The battery is a 55Wh (7300mAh) in a Samsung Ativ9 940X3G laptop
(productID: AA-PLVN4AR).

I've:
- Tried booting a live-usb with an old ubunut (14.04) with the same result
- Run the "Smart battery calibration" from BIOS with no difference 

Thanks,
Niklas

ProblemType: Bug
DistroRelease: Ubuntu 15.04
Package: upower 0.99.2-2
ProcVersionSignature: Ubuntu 3.19.0-20.20-generic 3.19.8
Uname: Linux 3.19.0-20-generic x86_64
ApportVersion: 2.17.2-0ubuntu1.1
Architecture: amd64
CurrentDesktop: Unity
Date: Sun Jun 14 18:34:00 2015
InstallationDate: Installed on 2015-04-24 (51 days ago)
InstallationMedia: Ubuntu 15.04 "Vivid Vervet" - Release amd64 (20150422)
SourcePackage: upower
UpgradeStatus: No upgrade log present (probably fresh install)

** Affects: upower (Ubuntu)
     Importance: Undecided
         Status: New


** Tags: amd64 apport-bug vivid

** Attachment added: "upower.dump"
   
https://bugs.launchpad.net/bugs/1465033/+attachment/4414745/+files/upower.dump

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1465033

Title:
  upower reports wrong battery info

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/upower/+bug/1465033/+subscriptions

-- 
ubuntu-bugs mailing list
[email protected]
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to