Install a P8 open power hardware PowerNV 8335-GTA  with ubuntu 14.04.1
as host OS. Upgraded firmware through in-band usb interface. Then
verified fru device description. Through in-band, fru device description
is showing empty fields.

1.Os and ipmitool versions
ubuntu@ltc-fire8:~$ uname -a
Linux ltc-fire8 3.19.0-30-generic #33~14.04.1-Ubuntu SMP Tue Sep 22 09:27:51 
UTC 2015 ppc64le ppc64le ppc64le GNU/Linux
ubuntu@ltc-fire8:~$

ubuntu@ltc-fire8:~$ cat /etc/os-release
NAME="Ubuntu"
VERSION="14.04.3 LTS, Trusty Tahr"
ID=ubuntu
ID_LIKE=debian
PRETTY_NAME="Ubuntu 14.04.3 LTS"
VERSION_ID="14.04"
HOME_URL="http://www.ubuntu.com/";
SUPPORT_URL="http://help.ubuntu.com/";
BUG_REPORT_URL="http://bugs.launchpad.net/ubuntu/";
ubuntu@ltc-fire8:~$

ubuntu@ltc-fire8:~$ which ipmitool
/usr/bin/ipmitool
ubuntu@ltc-fire8:~$ dpkg -S /usr/bin/ipmitool
ipmitool: /usr/bin/ipmitool
ubuntu@ltc-fire8:~$ dpkg --list | grep ipmitool
ii  ipmitool                                1.8.13-1ubuntu0.4                   
       ppc64el      utility for IPMI control with kernel driver or LAN interface
ubuntu@ltc-fire8:~$

2. Before firmware flash version of firmware
[pridhiviraj@localhost ~]$  ipmitool -I lanplus -H 9.40.193.53 -U ADMIN -P 
admin fru print 47
Product Name          : OpenPOWER Firmware
Product Version       : IBM-firestone-ibm-OP8_PFD_v1.6_0.29
Product Extra         :         hostboot-6847d73-b8d7c0a
Product Extra         :         occ-0726e69
Product Extra         :         skiboot-5.1.3-6221bd2
Product Extra         :         hostboot-binaries-43d5a59
Product Extra         :         firestone-xml-db1a93e-4ae8032
Product Extra         :         capp-ucode-105cb8f
[pridhiviraj@localhost ~]$

3. Done an in-band firmware update through below command.
ipmitool -v -I usb hpm upgrade 8335_810.1539.20150930n_update.hpm -z 32767 force

After flash new firmware level
[pridhiviraj@localhost ~]$ ipmitool -I lanplus -H 9.40.193.53 -U ADMIN -P admin 
fru print 47
Product Name          : OpenPOWER Firmware
Product Version       : IBM-firestone-ibm-OP8_v1.6_0.37
Product Extra         :         hostboot-bc98d0b-3385c16
Product Extra         :         occ-0362706
Product Extra         :         skiboot-5.1.5-9f8b09a
Product Extra         :         hostboot-binaries-43d5a59
Product Extra         :         firestone-xml-4db5666
Product Extra         :         capp-ucode-105cb8f
[pridhiviraj@localhost ~]$

4. Then verified in-band fru device description
ubuntu@ltc-fire8:~$ sudo ipmitool -I usb fru
[sudo] password for ubuntu:
FRU Device Description : Builtin FRU Device (ID 0)
Unknown FRU header version 0x00

FRU Device Description : AST2400
Unknown FRU header version 0x00

FRU Device Description : CPU 1 (ID 1)

FRU Device Description : CPU 2 (ID 2)

FRU Device Description : NODE 1 (ID 3)

FRU Device Description : MEMBUF1 (ID 4)

FRU Device Description : MEMBUF2 (ID 5)

FRU Device Description : MEMBUF3 (ID 6)

FRU Device Description : MEMBUF4 (ID 7)

FRU Device Description : MEMBUF5 (ID 8)

FRU Device Description : MEMBUF6 (ID 9)

FRU Device Description : MEMBUF7 (ID 10)

FRU Device Description : MEMBUF8 (ID 11)

FRU Device Description : DIMM1 (ID 12)

FRU Device Description : DIMM2 (ID 13)

FRU Device Description : DIMM3 (ID 14)

FRU Device Description : DIMM4 (ID 15)

FRU Device Description : DIMM5 (ID 16)

FRU Device Description : DIMM6 (ID 17)

FRU Device Description : DIMM7 (ID 18)

FRU Device Description : DIMM8 (ID 19)

FRU Device Description : DIMM9 (ID 20)

FRU Device Description : DIMM10 (ID 21)

FRU Device Description : DIMM11 (ID 22)

FRU Device Description : DIMM12 (ID 23)

FRU Device Description : DIMM13 (ID 24)

FRU Device Description : DIMM14 (ID 25)

FRU Device Description : DIMM15 (ID 26)

FRU Device Description : DIMM16 (ID 27)

FRU Device Description : DIMM17 (ID 28)

FRU Device Description : DIMM18 (ID 29)

FRU Device Description : DIMM19 (ID 30)

FRU Device Description : DIMM20 (ID 31)

FRU Device Description : DIMM21 (ID 32)

FRU Device Description : DIMM22 (ID 33)

FRU Device Description : DIMM23 (ID 34)

FRU Device Description : DIMM24 (ID 35)

FRU Device Description : DIMM25 (ID 36)

FRU Device Description : DIMM26 (ID 37)

FRU Device Description : DIMM27 (ID 38)

FRU Device Description : DIMM28 (ID 39)

FRU Device Description : DIMM29 (ID 40)

FRU Device Description : DIMM30 (ID 41)

FRU Device Description : DIMM31 (ID 42)

FRU Device Description : DIMM32 (ID 43)

FRU Device Description : GPU1 (ID 44)
Unknown FRU header version 0x00

FRU Device Description : GPU2 (ID 45)
Unknown FRU header version 0x00

FRU Device Description : FAN1 (ID 46)
Unknown FRU header version 0x00

FRU Device Description : System Firmware (ID 47)

FRU Device Description : PSU2 (ID 49)

FRU Device Description : PSU1 (ID 48)

FRU Device Description : FAN2 (ID 50)
Unknown FRU header version 0x00

FRU Device Description : FAN3 (ID 51)

FRU Device Description : FAN4 (ID 52)
Unknown FRU header version 0x00

ubuntu@ltc-fire8:~$

ubuntu@ltc-fire8:~$ sudo ipmitool fru
FRU Device Description : Builtin FRU Device (ID 0)
Unknown FRU header version 0x00

FRU Device Description : AST2400
Unknown FRU header version 0x00

FRU Device Description : CPU 1 (ID 1)

FRU Device Description : CPU 2 (ID 2)
Read FRU Area length 288 too large, Adjusting to 248
Board Mfg Date        : Sun Dec 31 18:00:00 1995

FRU Device Description : NODE 1 (ID 3)
Read FRU Area length 424 too large, Adjusting to 248
Chassis Type          : Unspecified
Read FRU Area length 328 too large, Adjusting to 208
Board Mfg Date        : Sun Dec 31 18:00:00 1995

FRU Device Description : MEMBUF1 (ID 4)
Read FRU Area length 288 too large, Adjusting to 248
Board Mfg Date        : Sun Dec 31 18:00:00 1995

FRU Device Description : MEMBUF2 (ID 5)
Read FRU Area length 288 too large, Adjusting to 248
Board Mfg Date        : Sun Dec 31 18:00:00 1995

FRU Device Description : MEMBUF3 (ID 6)
Read FRU Area length 288 too large, Adjusting to 248
Board Mfg Date        : Sun Dec 31 18:00:00 1995

FRU Device Description : MEMBUF4 (ID 7)
Read FRU Area length 288 too large, Adjusting to 248
Board Mfg Date        : Sun Dec 31 18:00:00 1995

FRU Device Description : MEMBUF5 (ID 8)
Read FRU Area length 288 too large, Adjusting to 248
Board Mfg Date        : Sun Dec 31 18:00:00 1995

FRU Device Description : MEMBUF6 (ID 9)
Read FRU Area length 288 too large, Adjusting to 248
Board Mfg Date        : Sun Dec 31 18:00:00 1995

FRU Device Description : MEMBUF7 (ID 10)
Read FRU Area length 288 too large, Adjusting to 248
Board Mfg Date        : Sun Dec 31 18:00:00 1995

FRU Device Description : MEMBUF8 (ID 11)
Read FRU Area length 288 too large, Adjusting to 248
Board Mfg Date        : Sun Dec 31 18:00:00 1995

FRU Device Description : DIMM1 (ID 12)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM2 (ID 13)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM3 (ID 14)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM4 (ID 15)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM5 (ID 16)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM6 (ID 17)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM7 (ID 18)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM8 (ID 19)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM9 (ID 20)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM10 (ID 21)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM11 (ID 22)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM12 (ID 23)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM13 (ID 24)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM14 (ID 25)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM15 (ID 26)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM16 (ID 27)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM17 (ID 28)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM18 (ID 29)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM19 (ID 30)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM20 (ID 31)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM21 (ID 32)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM22 (ID 33)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM23 (ID 34)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM24 (ID 35)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM25 (ID 36)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM26 (ID 37)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM27 (ID 38)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM28 (ID 39)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM29 (ID 40)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM30 (ID 41)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM31 (ID 42)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : DIMM32 (ID 43)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : GPU1 (ID 44)
Unknown FRU header version 0x00

FRU Device Description : GPU2 (ID 45)
Unknown FRU header version 0x00

FRU Device Description : FAN1 (ID 46)
Unknown FRU header version 0x00

FRU Device Description : System Firmware (ID 47)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : PSU2 (ID 49)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : PSU1 (ID 48)
Read FRU Area length 424 too large, Adjusting to 248

FRU Device Description : FAN2 (ID 50)
Unknown FRU header version 0x00

FRU Device Description : FAN3 (ID 51)
Read FRU Area length 480 too large, Adjusting to 192

FRU Device Description : FAN4 (ID 52)
Unknown FRU header version 0x00

ubuntu@ltc-fire8:~$

But out-of-band giving fru information

[pridhiviraj@localhost ~]$ ipmitool -I lanplus -H 9.40.193.53 -U ADMIN -P admin 
fru
FRU Device Description : Builtin FRU Device (ID 0)
Unknown FRU header version 0x00

FRU Device Description : CPU 1 (ID 1)
Board Mfg Date        : Mon Jan  1 05:30:00 1996
Board Mfg             : IBM
Board Product         : PROCESSOR MODULE
Board Serial          : YA1932791517
Board Part Number     : 00UM002
Board Extra           : ECID:019A0082C30C871808100000006E3CF7

FRU Device Description : CPU 2 (ID 2)
Board Mfg Date        : Mon Jan  1 05:30:00 1996
Board Mfg             : IBM
Board Product         : PROCESSOR MODULE
Board Serial          : YA1932791511
Board Part Number     : 00UM002
Board Extra           : ECID:019A0082801467180A07000000A33CF7

FRU Device Description : NODE 1 (ID 3)
Chassis Type          : Unknown
Chassis Part Number   : 8335-GTA
Chassis Serial        : 0000000000000000
Board Mfg Date        : Mon Jan  1 05:30:00 1996
Board Mfg             : IBM
Board Product         : SYSTEM PLANAR
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000

FRU Device Description : MEMBUF1 (ID 4)
Board Mfg Date        : Mon Jan  1 05:30:00 1996
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A00824224571810090000002C03A1

FRU Device Description : MEMBUF2 (ID 5)
Board Mfg Date        : Mon Jan  1 05:30:00 1996
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A0082401C67180E22000000890391

FRU Device Description : MEMBUF3 (ID 6)
Board Mfg Date        : Mon Jan  1 05:30:00 1996
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A0082400C871807200000002E0461

FRU Device Description : MEMBUF4 (ID 7)
Board Mfg Date        : Mon Jan  1 05:30:00 1996
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A0082400C8718201D0000008C03F1

FRU Device Description : MEMBUF5 (ID 8)
Board Mfg Date        : Mon Jan  1 05:30:00 1996
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A0082402447181F1D000000800391

FRU Device Description : MEMBUF6 (ID 9)
Board Mfg Date        : Mon Jan  1 05:30:00 1996
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A0082401C6718200C0000007F03F1

FRU Device Description : MEMBUF7 (ID 10)
Board Mfg Date        : Mon Jan  1 05:30:00 1996
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A0082402447180D0E0000002E0331

FRU Device Description : MEMBUF8 (ID 11)
Board Mfg Date        : Mon Jan  1 05:30:00 1996
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A0082401C6718141B000000280431

FRU Device Description : DIMM1 (ID 12)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b53

FRU Device Description : DIMM2 (ID 13)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b54

FRU Device Description : DIMM3 (ID 14)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295dba

FRU Device Description : DIMM4 (ID 15)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b0d

FRU Device Description : DIMM5 (ID 16)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b6e

FRU Device Description : DIMM6 (ID 17)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 402962f0

FRU Device Description : DIMM7 (ID 18)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b0c

FRU Device Description : DIMM8 (ID 19)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b2c

FRU Device Description : DIMM9 (ID 20)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40296547

FRU Device Description : DIMM10 (ID 21)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40297cde

FRU Device Description : DIMM11 (ID 22)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b27

FRU Device Description : DIMM12 (ID 23)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b34

FRU Device Description : DIMM13 (ID 24)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40298165

FRU Device Description : DIMM14 (ID 25)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40298126

FRU Device Description : DIMM15 (ID 26)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b56

FRU Device Description : DIMM16 (ID 27)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b2f

FRU Device Description : DIMM17 (ID 28)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295dbc

FRU Device Description : DIMM18 (ID 29)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 4029651b

FRU Device Description : DIMM19 (ID 30)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 4029651c

FRU Device Description : DIMM20 (ID 31)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 402982af

FRU Device Description : DIMM21 (ID 32)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40297cb9

FRU Device Description : DIMM22 (ID 33)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 402964de

FRU Device Description : DIMM23 (ID 34)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40296517

FRU Device Description : DIMM24 (ID 35)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b13

FRU Device Description : DIMM25 (ID 36)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 4085fcf7

FRU Device Description : DIMM26 (ID 37)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40279177

FRU Device Description : DIMM27 (ID 38)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 4085fbd5

FRU Device Description : DIMM28 (ID 39)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40297d08

FRU Device Description : DIMM29 (ID 40)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 4027a899

FRU Device Description : DIMM30 (ID 41)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 402790f3

FRU Device Description : DIMM31 (ID 42)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 4085fd22

FRU Device Description : DIMM32 (ID 43)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 4085fd23

FRU Device Description : GPU1 (ID 44)
Unknown FRU header version 0x00

FRU Device Description : GPU2 (ID 45)
Unknown FRU header version 0x00

FRU Device Description : FAN1 (ID 46)
Unknown FRU header version 0x00

FRU Device Description : System Firmware (ID 47)
Product Name          : OpenPOWER Firmware
Product Version       : IBM-firestone-ibm-OP8_v1.6_0.37
Product Extra         :         hostboot-bc98d0b-3385c16
Product Extra         :         occ-0362706
Product Extra         :         skiboot-5.1.5-9f8b09a
Product Extra         :         hostboot-binaries-43d5a59
Product Extra         :         firestone-xml-4db5666
Product Extra         :         capp-ucode-105cb8f

FRU Device Description : PSU2 (ID 49)
Product Manufacturer  : EMER
Product Name          : Texan1300W
Product Part Number   : 00FX880
Product Version       : 0.12
Product Serial        : 55603S
Product Asset Tag     : 0.1

FRU Device Description : PSU1 (ID 48)
Product Manufacturer  : EMER
Product Name          : Texan1300W
Product Part Number   : 00FX880
Product Version       : 0.12
Product Serial        : 55601E
Product Asset Tag     : 0.1

FRU Device Description : FAN2 (ID 50)
Unknown FRU header version 0x00

FRU Device Description : FAN3 (ID 51)
Product Manufacturer  : IBM
Product Name          : skiboot
Product Version       : 5.1.2-3e77f72
Product Extra         : ?

FRU Device Description : FAN4 (ID 52)
Unknown FRU header version 0x00
Tested with latest ipmitool from sourceforge using below commands.
git clone git://git.code.sf.net/p/ipmitool/source
cd source/
./bootstrap
./configure
make

With this latest ipmitool 1.8.15, fru information is giving same as out-
of-band fru information.

ubuntu@ltc-fire8:~/source$ cd src/
ubuntu@ltc-fire8:~/source/src$ ls
ipmievd    ipmievd.o    ipmishell.o  ipmitool.c  Makefile     Makefile.in
ipmievd.c  ipmishell.c  ipmitool     ipmitool.o  Makefile.am  plugins
ubuntu@ltc-fire8:~/source/src$ ./ipmitool -V
ipmitool version 1.8.15-cvs

ubuntu@ltc-fire8:~/source/src$ sudo ./ipmitool fru
FRU Device Description : Builtin FRU Device (ID 0)
Unknown FRU header version 0x00

FRU Device Description : CPU 1 (ID 1)
Board Mfg Date        : Sun Dec 31 18:00:00 1995
Board Mfg             : IBM
Board Product         : PROCESSOR MODULE
Board Serial          : YA1932791517
Board Part Number     : 00UM002
Board Extra           : ECID:019A0082C30C871808100000006E3CF7

FRU Device Description : CPU 2 (ID 2)
Board Mfg Date        : Sun Dec 31 18:00:00 1995
Board Mfg             : IBM
Board Product         : PROCESSOR MODULE
Board Serial          : YA1932791511
Board Part Number     : 00UM002
Board Extra           : ECID:019A0082801467180A07000000A33CF7

FRU Device Description : NODE 1 (ID 3)
Chassis Type          : Unknown
Chassis Part Number   : 8335-GTA
Chassis Serial        : 0000000000000000
Board Mfg Date        : Sun Dec 31 18:00:00 1995
Board Mfg             : IBM
Board Product         : SYSTEM PLANAR
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000

FRU Device Description : MEMBUF1 (ID 4)
Board Mfg Date        : Sun Dec 31 18:00:00 1995
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A00824224571810090000002C03A1

FRU Device Description : MEMBUF2 (ID 5)
Board Mfg Date        : Sun Dec 31 18:00:00 1995
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A0082401C67180E22000000890391

FRU Device Description : MEMBUF3 (ID 6)
Board Mfg Date        : Sun Dec 31 18:00:00 1995
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A0082400C871807200000002E0461

FRU Device Description : MEMBUF4 (ID 7)
Board Mfg Date        : Sun Dec 31 18:00:00 1995
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A0082400C8718201D0000008C03F1

FRU Device Description : MEMBUF5 (ID 8)
Board Mfg Date        : Sun Dec 31 18:00:00 1995
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A0082402447181F1D000000800391

FRU Device Description : MEMBUF6 (ID 9)
Board Mfg Date        : Sun Dec 31 18:00:00 1995
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A0082401C6718200C0000007F03F1

FRU Device Description : MEMBUF7 (ID 10)
Board Mfg Date        : Sun Dec 31 18:00:00 1995
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A0082402447180D0E0000002E0331

FRU Device Description : MEMBUF8 (ID 11)
Board Mfg Date        : Sun Dec 31 18:00:00 1995
Board Mfg             : IBM
Board Product         : DDR3 MEM RISER
Board Serial          : 0000000000000000
Board Part Number     : 0000000000000000
Board Extra           : ECID:019A0082401C6718141B000000280431

FRU Device Description : DIMM1 (ID 12)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b53

FRU Device Description : DIMM2 (ID 13)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b54

FRU Device Description : DIMM3 (ID 14)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295dba

FRU Device Description : DIMM4 (ID 15)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b0d

FRU Device Description : DIMM5 (ID 16)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b6e

FRU Device Description : DIMM6 (ID 17)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 402962f0

FRU Device Description : DIMM7 (ID 18)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b0c

FRU Device Description : DIMM8 (ID 19)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b2c

FRU Device Description : DIMM9 (ID 20)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40296547

FRU Device Description : DIMM10 (ID 21)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40297cde

FRU Device Description : DIMM11 (ID 22)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b27

FRU Device Description : DIMM12 (ID 23)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b34

FRU Device Description : DIMM13 (ID 24)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40298165

FRU Device Description : DIMM14 (ID 25)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40298126

FRU Device Description : DIMM15 (ID 26)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b56

FRU Device Description : DIMM16 (ID 27)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b2f

FRU Device Description : DIMM17 (ID 28)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295dbc

FRU Device Description : DIMM18 (ID 29)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 4029651b

FRU Device Description : DIMM19 (ID 30)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 4029651c

FRU Device Description : DIMM20 (ID 31)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 402982af

FRU Device Description : DIMM21 (ID 32)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40297cb9

FRU Device Description : DIMM22 (ID 33)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 402964de

FRU Device Description : DIMM23 (ID 34)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40296517

FRU Device Description : DIMM24 (ID 35)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40295b13

FRU Device Description : DIMM25 (ID 36)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 4085fcf7

FRU Device Description : DIMM26 (ID 37)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40279177

FRU Device Description : DIMM27 (ID 38)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 4085fbd5

FRU Device Description : DIMM28 (ID 39)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 40297d08

FRU Device Description : DIMM29 (ID 40)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 4027a899

FRU Device Description : DIMM30 (ID 41)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 402790f3

FRU Device Description : DIMM31 (ID 42)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 4085fd22

FRU Device Description : DIMM32 (ID 43)
Product Manufacturer  : ce80
Product Name          : 0b
Product Part Number   : M393B2G70EB0-YK0
Product Version       : 0000
Product Serial        : 4085fd23

FRU Device Description : GPU1 (ID 44)
Unknown FRU header version 0x00

FRU Device Description : GPU2 (ID 45)
Unknown FRU header version 0x00

FRU Device Description : FAN1 (ID 46)
Unknown FRU header version 0x00

FRU Device Description : System Firmware (ID 47)
Product Name          : OpenPOWER Firmware
Product Version       : IBM-firestone-ibm-OP8_v1.6_0.37
Product Extra         :         hostboot-bc98d0b-3385c16
Product Extra         :         occ-0362706
Product Extra         :         skiboot-5.1.5-9f8b09a
Product Extra         :         hostboot-binaries-43d5a59
Product Extra         :         firestone-xml-4db5666
Product Extra         :         capp-ucode-105cb8f

FRU Device Description : PSU2 (ID 49)
Product Manufacturer  : EMER
Product Name          : Texan1300W
Product Part Number   : 00FX880
Product Version       : 0.12
Product Serial        : 55603S
Product Asset Tag     : 0.1

FRU Device Description : PSU1 (ID 48)
Product Manufacturer  : EMER
Product Name          : Texan1300W
Product Part Number   : 00FX880
Product Version       : 0.12
Product Serial        : 55601E
Product Asset Tag     : 0.1

FRU Device Description : FAN2 (ID 50)
Unknown FRU header version 0x00

FRU Device Description : FAN3 (ID 51)
Product Manufacturer  : IBM
Product Name          : skiboot
Product Version       : 5.1.2-3e77f72
Product Extra         : 1

FRU Device Description : FAN4 (ID 52)
Unknown FRU header version 0x00

with distro proposed tool fru information is not coming

ubuntu@ltc-fire8:~$ sudo ipmitool -V
ipmitool version 1.8.13
ubuntu@ltc-fire8:~$ dpkg --list | grep ipmitool
ii  ipmitool                                1.8.13-1ubuntu0.4                   
       ppc64el      utility for IPMI control with kernel driver or LAN interface
ubuntu@ltc-fire8:~$
ubuntu@ltc-fire8:~$ sudo ipmitool fru
FRU Device Description : Builtin FRU Device (ID 0)
Unknown FRU header version 0x00

FRU Device Description : AST2400
Unknown FRU header version 0x00

FRU Device Description : CPU 1 (ID 1)

FRU Device Description : CPU 2 (ID 2)
Read FRU Area length 288 too large, Adjusting to 248
Board Mfg Date        : Sun Dec 31 18:00:00 1995

FRU Device Description : NODE 1 (ID 3)
Read FRU Area length 312 too large, Adjusting to 248
Chassis Type          : Unspecified
Read FRU Area length 328 too large, Adjusting to 208
Board Mfg Date        : Sun Dec 31 18:00:00 1995

FRU Device Description : MEMBUF1 (ID 4)
Read FRU Area length 288 too large, Adjusting to 248
Board Mfg Date        : Sun Dec 31 18:00:00 1995

FRU Device Description : MEMBUF2 (ID 5)
Read FRU Area length 288 too large, Adjusting to 248
Board Mfg Date        : Sun Dec 31 18:00:00 1995

FRU Device Description : MEMBUF3 (ID 6)
Read FRU Area length 288 too large, Adjusting to 248
Board Mfg Date        : Sun Dec 31 18:00:00 1995
(In reply to comment #3)
> Tested with latest ipmitool from sourceforge using below commands.
> git clone git://git.code.sf.net/p/ipmitool/source
> cd source/
> ./bootstrap
> ./configure
> make
>
> With this latest ipmitool 1.8.15, fru information is giving same as
> out-of-band fru information.
>
Thanks. That means we require additional fix to be back-ported to 14.04.03.

Breno/Sudipto, can we get help from AMI to identify the fix and get it 
backported ?
Routing to BugsAgainstDistros as this seems to be Ubuntu ipmitool missing some 
patch.

** Changed in: ubuntu
     Assignee: (unassigned) => Taco Screen team (taco-screen-team)

-- 
You received this bug notification because you are a member of Ubuntu
Bugs, which is subscribed to Ubuntu.
https://bugs.launchpad.net/bugs/1512954

Title:
  Process accounting deadlock with idmapd callout when writing to NFSv4
  mount

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+bug/1512954/+subscriptions

-- 
ubuntu-bugs mailing list
ubuntu-bugs@lists.ubuntu.com
https://lists.ubuntu.com/mailman/listinfo/ubuntu-bugs

Reply via email to